Animal Mini Veterinary Real-time Data Handheld Pulse Oximeter
Description
-
Professional Hospital Use Vet Medical Hospital Equipment Animal Use Hot Sale Veterinary Pulse Oximeter
Products Description
Introduction:VET Pulse Oximeter adopts Photoelectric Oxyhemoglobin Inspection Technology in accordance with Capacity Pulse Scanning &Recording Technology, which can be used to measure SpO2 and pulse through animal’s tongue or ear. It is applicable for use in pet hospital, vet clinic ,etc.Features:1. Small in volume, light in weight and convenient to carry.2. Easy and simple to operate, low in power consumption.3. With function menu.4. Display of SpO2 value.5. Display of PR value and bar graph.6. Display of pulse waveform.7. Adjustable screen brightness, PR sound indication.8. Review function.9. Clock function.10. Audible prompt for over-limit and low battery.11. Battery status indication.12. Low battery indication.13. Storage function for SpO2 and PR values, and data stored can be uploaded to PC.14. Real-time data can be uploaded to PC.15. External SpO2 probe can be connected.Physical characteristic:Dimension: 110 mmL × 60 mmW × 24 mmHWeight: about 120 gincluding batteryWhat is included in the package?One main unitTongue SPO2 ProbeTow batteriesOnly to US customerUser manualUSB cableCDPC software Features for our vet pulse oximeterSmall in volume,light in weight and convenient in carryingSpO2 value display,Pulse rate value display, bar graph display,Pulse waveform displayWith SpO2 value and pulse rate value of storage, the storage data can be uploaded to computersReal-time data can be transmitted to computersConnected with an external SPO2 probe.tongue probe
Product Paramenters
|
Screen Resolution
|
160*128
|
|
SpO2 Measuring Range
|
0%~100%, the resolution is 1%. Accuracy:70%~100%:±2% ,Below 70% unspecified.
|
|
PR Measuring Range
|
30bpm~250bpm, the resolution is 1bpm Accuracy:±2bpm or ±2% select larger
|
|
Measurement Performance in Weak Filling Condition
|
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%.SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%
select larger. |
|
Resistance to surrounding light
|
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less
than ±1%. |
|
Power Consumption
|
less than 100mA
|
|
Voltage
|
DC 2.6V~3.6V
|
|
Power Supply
|
Dry battery2AA
|
|
Battery working hour
|
The oretical number is 44 hours
|
Additional information
| Color | White |
|---|---|
| Material | Nylon |