Pathology Tissue Processor 1500ml Large Capacity Laboratory Automated Tissue Processor
Description
Product Description

|
Number of cylinders |
1410 reagent cylinders,4 paraffin cylinders |
|
Number of tissue baskets |
2Two baskets and two programs areable to run together at the same time. |
|
Station capacity |
1500mlIt can contain more than 300pcs tissue samplesor120pcs disposable embedding cassettes |
|
Set temperature |
0°C-99℃ |
|
Set time per cylinder |
1m inute~99 minutes 59 seconds |
|
Storable program |
9 sets |
|
The baskets rising and staying time |
30 seconds |
|
The baskets” shaking frequency in the cylinder |
4 times per 10 minutes to improve immersing efficiency. |
|
Power-on delayed setting |
99 hours and 59 minutes |
|
Dimensions |
140x50x55cm |
|
Power |
≤900W |
|
Voltage |
220V/50Hz or 110V/60Hz |
Feature
* It is a bench-top linear closed tissue processor, a compact instrument designed for complete automatic from dehydration and infiltration of biological samples to the final paraffin bath process. * Includes 14 stations for simultaneous processing of two sample baskets programmable separately * All the reagent and paraffin containers are closed to prevent evaporation
* Ion purification function: prevent solvent odors and pollution.
* Automatic locating and memorizing function.
* It can find the starting position and memorize it every time automatically in order to ensure that there is no wrong cylinder phenomenon in each operation. Besides, each cylinder uses a separate positioning method to improve positioning accuracy.
* All the operating parameters, like station time, temperatures, and dripping time, can be easily set by the touch-screen panel, as well as daily,weekend,and weekly programming.
* Temperatures are regulated via an electronic thermostat with a microprocessor., Users can set up to 9 different programs.
* The paraffin cylinder adopts dry heating and there’s no need to add water. in this way, it becomes safe and reliable without lack-of-water, corrosion, electric leakage, and water leakage problems.
* If the machine comes up with cylinder-stuck phenomenon,it will automatically stop working and give an alarm in order to protect the tissue from damaging and make the machine safe. * Each program can be modified partly.There’s no need to rewrite the program.
* There is an external USB power connector need to equip a power supply for 1-10 hours working by yourself to avoid tissue dehydration caused by power-off for a long time.
Pathology Tissue Processor 1500ml Large Capacity Laboratory Automated Tissue Processor
Roundfin Lab Fully Automated Histology Tissue Stainer Slide Processing Stainer
Automatic Tissue Stainer Laboratory Medical Histopathology Tissue Processor Clinical Analytical Instruments 1000ml Capacity
Parameters
1.Number of cylinders: 18
One cleaning cylinder, one drying cylinder
2.Capacity:1000ml
Single basket 47 slides
3.Operation mode:Running multiple baskets continuously
Continuous batch dyeing
4.Set time per cylinder:1 second~99 minutes 59 seconds
5. Set temperature:0°C~99°C
6. Storable program:6 sets
7.The basket rises and trembles:0-10 times
8.Dimensions:140×50×55cm
Function
1.Can continuously run the dye box
Multiple dye racks can be run at the same time for continuous batch dyeing
Can meet large quantities of work
2.Color LCD touch screen display
Icon display, showing all operating parameters, intuitive and clear. Can directly modify the parameters on the icon display, touch screen operation, easy to use 3 Withion purification
Commonly used reagents such as xylene, which volatilizes in the air, are harmful to the human body. Commonly used air purification uses activated carbon adsorption purification, that is, physical purification. Activated carbon purification requires a certain adsorption temperature 60 °C ~ 70 °C in the first stage, 20 °C ~ 40 °C in the second stage and a certain adsorption time 1 hour or so to completely remove. The moisture and dust in the air will affect the activity of activated carbon, thus affecting its effectiveness, so it must be replaced or regenerated.
3.Ion purification can overcome the above drawbacks. Ion purifying produces ions by ionizing gases, changing and decomposing harmful gases hydrocarbons that can completely remove harmful substances without maintenance
4.Six programs can be stored
Six common operating procedures can be stored.
5.Automatic location memory function
Each time it runs automatically, it can find the starting position and memorize it to ensure that the wrong cylinder phenomenon does not occur in each run, and each cylinder uses a separate positioning method to increase the positioning accuracy.
6. With alarm function, such as the dyeing rack into the end of the cylinder, the front staining rack is still not taken away at the end of the cylinder, there is an alarm to promptly handle.
7.Anti-card cylinder function
8.With drying cylinder
9.Automatic water inlet, drainage
Automatic water drainage, with overflow protection
10.The running parts adopt bearing linear guides, which have high precision, low resistance, stable operation and wear resistance, and can maintain their reliability for a long time.
Additional information
| Material | Plastic |
|---|---|
| Safety standard | GB15979-2002 |









Reviews
There are no reviews yet.